Generator Size Calculator

Sum simultaneous running loads and one largest additional start demand.

Starting values are examples. Adjust them for your project.

For example, include a fridge, lights and router only if used together. Add each label’s electrical watts; do not use cooling BTU/h.

A fridge, pump or aircon motor may draw extra power at startup. Use the largest one-appliance difference from actual model data.

See how the calculation works

Enter your details to see the drawing.

Edit measurements ↑ Measurements and worked example ↓

Your diagram

Find the generator wattage needed

Check running and starting watts, using one largest extra start demand when motors start one at a time.

Back to calculator ↑

List simultaneous loads

Sum running watts for everything used together. Find the largest difference between one appliance’s starting and running watts.

List what will run in the same outage scenario, not every appliance in the house. If a label provides amps and voltage instead of watts, confirm how to interpret it for that device, especially motors and loads with power factor. Actual demand can differ from marketing or maximum figures.

Read both generator ratings

Generators have running and short-duration starting ratings. Compare each load with its matching rating. Do not sum every motor surge if they start sequentially.

Additional starting watts are the excess above one appliance’s running power. If it runs at 500 W and starts at 1,700 W, enter 1,200 W extra. This assumes other loads are already running and this appliance starts separately; adding the full 1,700 W again would double-count its 500 W running load.

Worked default example

Running load 1,800 W plus the largest extra start demand 1,200 W gives 3,000 W starting estimate. Sizing mode shows at least 1,800 W running and 3,000 W starting requirement. If you have a candidate generator, switch to comparison mode and enter both nameplate ratings.

Even when both running and starting totals fit, an individual outlet may have a lower limit than the whole generator. Check outlet ratings too.

Check limitations before use

This comparison does not check voltage, phase, surge duration or power quality. Run generators outdoors per the manual and use a qualified electrician for home connections.

If several motors start together or equipment is sensitive to power quality, have a professional assess the actual load, voltage, phase and frequency. Never feed generator power backward through home wiring. Operate the engine outdoors away from openings as its manual directs to prevent carbon monoxide exposure.

A negative running or starting headroom means the entered load exceeds that corresponding rating; a positive other headroom does not make the comparison pass. Remove simultaneous loads or consult the manufacturer about real capacity and startup sequence. This arithmetic does not derate for altitude, temperature or machine condition.

Common questions

Should I add every appliance’s starting watts?

This estimate uses one largest extra start demand for sequential starts; simultaneous starts need another assessment.

Does passing mean it is safe to connect?

No. Voltage, phase, protection and connection need checking.

Can I run it in a garage with the door open?

No. Operate outdoors following manufacturer warnings.

Sources and calculation guidance

Check these against your chosen product’s label and instructions.